*If not stated otherwise, the technical data apply to all versions of the PR 6423.
Measuring range : static (±1,0 mm) dynamic: (0…50…500 µm)
Sensitivity : 8 V/mm
Measuring target : Material : (Electrically conducting steel)
Form of the measuring target : (Cylindrical shafts, plain surfaces, measuring collars at machine shafts)
Height of the measuring collar on the shaft surface with 1% additional error : (≥25 mm)
Peripheral speed of the shaft : (0…2500 m/s)
Shaft diameter : (≥25 mm)
Nominal gap (centre of measuring range) : (1,5 mm)
Measuring error : After calibration and in connection with a CON 0.., the specification are related to the f.s.d. Linearity error : (≤ ±1 %)
Temperature error : – Zero point : (200 mV / 100 K)
– Sensitivity : (< 2%/100 K)
– Long-term drift : (0,3 % max)
– Influence of supply voltage : (<20 mV / V)
Operating temperature range : (-35…+180°C) short-term : (up to +200°C)
Temperature range for storage and transport : (-40…+70°C)
Thread of sensor housing : (M10 x 1 or 3/8“-24-UNF-2A)
Housing material : Stainless Steel
Endurance to pressure (uniform influence on transducer and cable) : 2 bar
Vibration and shock (nominal values at max. 25 C) : 5 g at 60 Hz
Cable length : PR 6423/000-000; PR 6423/100-000; PR 6423/010-000
(1 m at the transducer + 3 m extension cable)
Other cable lengths possible according to order matrix.
Max. cable temperature : +200°C
Connection of transducers to converters CON 011/CON 021 : Lemo plug
Connection of transducers to converters CON 031/CON 041 : open cable ends for screw terminal
Direct connection of PR 6423 with Lemo – plug to the following
MMS 3000 transmitters : MMS 3110; MMS 3210; MMS 3311
Cable protection : PTFE
Weight : net weight without / with metal protection tube : (0,1 / 0,3 kg)
gross weight without/with metal protection tube : (0,2 / 0,5 kg)