SPESIFIKASI :
Operating voltage (10 … 35 VDC, 24 VAC ± 20%)
with optional power supply module (100 … 240 VAC 50/60 Hz)
Power consumption @ 20 °C (Uin 24VDC)
RS232 max. 25 mA
Uout 2 x 0…1V / 0…5V / 0…10V max. 25 mA
Iout 2 x 0…20 mA max. 60 mA
display and backlight + 20 mA
Analog outputs (2 standard, 3rd optional)
current output 0 … 20 mA, 4 … 20 mA
voltage output 0 … 1 V, 0 … 5 V, 0 … 10 V
Accuracy of analog outputs at (20 °C ± 0.05% full scale)
Temperature dependence of the
analog outputs ± 0.005%/°C full scale
External loads
current outputs RL < 500 ohm
0 … 1V output RL > 2 kohm
0 … 5V and 0 … 10V outputs RL > 10 kohm
Max. wire size (0.5 mm2 (AWG 20) stranded wires recommended)
Digital outputs (RS232, RS485 (optional))
Protocols (ASCII commands, MODBUS RTU)
Service connection (RS232, USB)
Relay outputs (0.5 A, 250 VAC, SPDT, potential-free (optional))
Ethernet interface (optional)
Supported standards (10BASE-T, 100BASE-TX)
Connector (8P8C / RJ45)
IPv4 address assignment (DHCP (automatic), static)
Protocols (Telnet, MODBUS TCP/IP)
WLAN interface (optional)
Supported standards (802.11b)
Antenna connector type (RP-SMA)
IPv4 address assignment (DHCP (automatic), static)
Protocols (Telnet, MODBUS TCP/IP)
Security (WEP 64/128, WPA)
Authentication / Encryption
Open / no encryption
Open / WEP
WPA Pre-shared key / TKIP
WPA Pre-shared key / CCMP (a.k.a. WPA2)
Optional data logger with real-time clock
Logged parameters (max. four with trend/min/max values)
Logging interval (10 sec. fixed)
Max. logging period (4 years, 5 months)
Logged points (13.7 million points per parameter)
Battery lifetime (min. 5 years)
Display (LCD with backlight, graphical trend display of any parameter)
Menu languages English, Chinese, Finnish, French, German, Japanese, Russian, Spanish, Swedish